Scribe v2 Medical
under 1out of 100same as last month
Summary
Scribe v2 Medical is a batch transcription model fine-tuned for clinical audio. ElevenLabs reports 35% fewer transcription errors on clinical audio than Scribe v2, especially around medication names, anatomy, pathology, and clinical dictation. The provider says everyday speech retains the general model’s accuracy.
The result remains a draft for documentation. A healthcare professional or another authorized reviewer must check and correct it before use. The model does not diagnose conditions or provide treatment recommendations. For live transcription, ElevenLabs points to Scribe v2 Realtime, not this clinical batch variant.
On this page
All benchmark results
Every published result with its source, test setup and comparison models.
Show all 23 published benchmark results
Page 1 of 2
Measurements without matching peer values
These measurements have no matching peer values under the same test conditions. Their original values and sources remain available here.
ElevenLabs MedDictate overall WER (Show measurement, test conditions, and source)
- Source value
- 4.9
- Score
- 4.9
- Metric
- overall WER
- Unit
- %
- Benchmark version
- Corti MedDictate; evaluator edition not stated
- Category
- audio
- Direction
- Lower is better
- Sample
- 40
- Source type
- vendor-reported
- Evaluator
- ElevenLabs model evaluation
- Status
- active
- Retrieved at
- 2026-10-15
- Methodology
- Vendor-reported result. Vendor evaluation on Corti MedDictate: English, French, and German clinical dictation. The public test split has 40 clips (24 EN, 7 FR, 9 DE); overall aggregation details are not stated.
ElevenLabs MedTerm medical-term recall (Show measurement, test conditions, and source)
- Source value
- 77.7
- Score
- 77.7
- Metric
- recall of annotated medical terms
- Unit
- %
- Benchmark version
- Corti MedTerm (600 samples)
- Category
- audio
- Direction
- Higher is better
- Sample
- 600
- Source type
- vendor-reported
- Evaluator
- ElevenLabs model evaluation
- Status
- active
- Retrieved at
- 2026-10-15
- Methodology
- Vendor-reported result. Vendor evaluation on Corti MedTerm, a public 600-sample clinical-terminology benchmark; term-WER scores annotated medical terms only.
ElevenLabs MedTerm medical-term WER (Show measurement, test conditions, and source)
- Source value
- 10.4
- Score
- 10.4
- Metric
- term-WER
- Unit
- %
- Benchmark version
- Corti MedTerm (600 samples)
- Category
- audio
- Direction
- Lower is better
- Sample
- 600
- Source type
- vendor-reported
- Evaluator
- ElevenLabs model evaluation
- Status
- active
- Retrieved at
- 2026-10-15
- Methodology
- Vendor-reported result. Vendor evaluation on Corti MedTerm, a public 600-sample clinical-terminology benchmark; term-WER scores annotated medical terms only.
ElevenLabs Eka Medical ASR semantic WER (Show measurement, test conditions, and source)
- Source value
- 6.5
- Score
- 6.5
- Metric
- semantic WER
- Unit
- %
- Benchmark version
- Eka Medical ASR; evaluator edition not stated
- Category
- audio
- Direction
- Lower is better
- Sample
- 3619
- Source type
- vendor-reported
- Evaluator
- ElevenLabs model evaluation
- Status
- active
- Retrieved at
- 2026-10-15
- Methodology
- Vendor-reported result. Vendor evaluation on public Eka Medical ASR, 3,619 English clinical-audio samples; semantic WER counts meaning-equivalent formatting as equivalent.
ElevenLabs Eka Medical ASR keyword WER (Show measurement, test conditions, and source)
- Source value
- 6.02
- Score
- 6.02
- Metric
- keyword WER
- Unit
- %
- Benchmark version
- Eka Medical ASR; evaluator edition not stated
- Category
- audio
- Direction
- Lower is better
- Sample
- 3619
- Source type
- vendor-reported
- Evaluator
- ElevenLabs model evaluation
- Status
- active
- Retrieved at
- 2026-10-15
- Methodology
- Vendor-reported result. Vendor evaluation on public Eka Medical ASR, 3,619 English clinical-audio samples; keyword-WER scores annotated medical keywords only.
Eka Medical ASR WER on isolated single-word terms (Show measurement, test conditions, and source)
- Source value
- 14.3
- Score
- 14.3
- Metric
- word error rate on isolated annotated terms
- Unit
- %
- Benchmark version
- Eka Medical ASR; isolated-term subset
- Category
- speech-to-text
- Direction
- Lower is better
- Source type
- vendor-reported
- Evaluator
- ElevenLabs Scribe v2 Medical evaluation
- Status
- active
- Retrieved at
- 2026-10-17
- Methodology
- Vendor-reported result. ElevenLabs-reported Eka Medical ASR result on the public dataset described as 3,619 English clinical audio samples with medical-term annotations. The row is a term-level WER subset, not the existing whole-transcript semWER or the existing whole-set keyword-WER row. The source describes clinical sentence and isolated single-term conditions but does not give their per-subset sample counts or scoring procedure.
- Context
- Subset N and confidence intervals are not published. The aggregate annotated-term figure of 9.5% was excluded because its relationship to the existing Eka keyword-WER row is not clear enough to avoid a duplicate.
Eka Medical ASR term WER in clinical sentences (Show measurement, test conditions, and source)
- Source value
- 7.5
- Score
- 7.5
- Metric
- medical-term word error rate
- Unit
- %
- Benchmark version
- Eka Medical ASR; clinical-sentence subset
- Category
- speech-to-text
- Direction
- Lower is better
- Source type
- vendor-reported
- Evaluator
- ElevenLabs Scribe v2 Medical evaluation
- Status
- active
- Retrieved at
- 2026-10-17
- Methodology
- Vendor-reported result. ElevenLabs-reported Eka Medical ASR result on the public dataset described as 3,619 English clinical audio samples with medical-term annotations. The row is a term-level WER subset, not the existing whole-transcript semWER or the existing whole-set keyword-WER row. The source describes clinical sentence and isolated single-term conditions but does not give their per-subset sample counts or scoring procedure.
- Context
- Subset N and confidence intervals are not published. The aggregate annotated-term figure of 9.5% was excluded because its relationship to the existing Eka keyword-WER row is not clear enough to avoid a duplicate.
Corti MedDictate clinical dictation WER, English (Show measurement, test conditions, and source)
- Source value
- 3
- Score
- 3
- Metric
- Word error rate (WER)
- Unit
- %
- Benchmark version
- Corti MedDictate; ElevenLabs evaluation article updated 2026-10-12
- Category
- speech recognition
- Direction
- Lower is better
- Source type
- vendor-reported
- Evaluator
- ElevenLabs, Scribe v2 Medical evaluation
- Status
- active
- Retrieved at
- 2026-10-17
- Methodology
- Vendor-reported result. Official ElevenLabs comparison on Corti MedDictate clinical dictation; exact source table label "Scribe v2 Medical" and model_id=scribe_v2_medical; locale EN; reported metric WER. Locale sample count, decoding settings, and immutable serving revision are not published.
- Context
- Vendor-reported result; the article does not publish locale-level N, decoding settings, or an immutable served-model revision. This locale row is distinct from the article's already-recorded overall WER.
Corti MedDictate clinical dictation WER, French (Show measurement, test conditions, and source)
- Source value
- 8.3
- Score
- 8.3
- Metric
- Word error rate (WER)
- Unit
- %
- Benchmark version
- Corti MedDictate; ElevenLabs evaluation article updated 2026-10-12
- Category
- speech recognition
- Direction
- Lower is better
- Source type
- vendor-reported
- Evaluator
- ElevenLabs, Scribe v2 Medical evaluation
- Status
- active
- Retrieved at
- 2026-10-17
- Methodology
- Vendor-reported result. Official ElevenLabs comparison on Corti MedDictate clinical dictation; exact source table label "Scribe v2 Medical" and model_id=scribe_v2_medical; locale FR; reported metric WER. Locale sample count, decoding settings, and immutable serving revision are not published.
- Context
- Vendor-reported result; the article does not publish locale-level N, decoding settings, or an immutable served-model revision. This locale row is distinct from the article's already-recorded overall WER.
Corti MedDictate clinical dictation WER, German (Show measurement, test conditions, and source)
- Source value
- 7.2
- Score
- 7.2
- Metric
- Word error rate (WER)
- Unit
- %
- Benchmark version
- Corti MedDictate; ElevenLabs evaluation article updated 2026-10-12
- Category
- speech recognition
- Direction
- Lower is better
- Source type
- vendor-reported
- Evaluator
- ElevenLabs, Scribe v2 Medical evaluation
- Status
- active
- Retrieved at
- 2026-10-17
- Methodology
- Vendor-reported result. Official ElevenLabs comparison on Corti MedDictate clinical dictation; exact source table label "Scribe v2 Medical" and model_id=scribe_v2_medical; locale DE; reported metric WER. Locale sample count, decoding settings, and immutable serving revision are not published.
- Context
- Vendor-reported result; the article does not publish locale-level N, decoding settings, or an immutable served-model revision. This locale row is distinct from the article's already-recorded overall WER.
Scribe v2 Medical, M-WER (Show measurement, test conditions, and source)
- Source value
- 1.08
- Score
- 1.08
- Metric
- Medical word error rate over medical reference tokens
- Unit
- %
- Benchmark version
- Omi Health Medical Speech-to-Text Benchmark, edition 2026-09-26.1; batch
- Category
- speech-to-text
- Direction
- Lower is better
- Sample
- 1513
- Source type
- community-reported
- Evaluator
- Omi Health Medical Speech-to-Text Benchmark
- Status
- active
- Retrieved at
- 2026-10-17
- Methodology
- Community-reported result. Omi Health Medical Speech-to-Text Benchmark, edition 2026-09-26.1, batch transcription. Exact table row “ElevenLabs Scribe v2 Medical”; 1,513 English recordings totaling 7.2 hours. The table states 2,872 medical reference tokens, 442 drug references, and 94 dose/unit events. Batch latency uses 600 measurements; Omi says ElevenLabs endpoints were timed from Frankfurt in September 2026.
- Context
- Omi Health sells a competing commercial medical speech-to-text product. Treat this benchmark conservatively as a community/vendor report, not a neutral independent replication. Omi does not state an immutable model revision, complete decoder parameters, or confidence intervals. Results apply only to the stated Omi test edition and route.
Scribe v2 Medical, drug-term error rate (Show measurement, test conditions, and source)
- Source value
- 0.45
- Score
- 0.45
- Metric
- Errors over drug-term references
- Unit
- %
- Benchmark version
- Omi Health Medical Speech-to-Text Benchmark, edition 2026-09-26.1; batch
- Category
- speech-to-text
- Direction
- Lower is better
- Sample
- 1513
- Source type
- community-reported
- Evaluator
- Omi Health Medical Speech-to-Text Benchmark
- Status
- active
- Retrieved at
- 2026-10-17
- Methodology
- Community-reported result. Omi Health Medical Speech-to-Text Benchmark, edition 2026-09-26.1, batch transcription. Exact table row “ElevenLabs Scribe v2 Medical”; 1,513 English recordings totaling 7.2 hours. The table states 2,872 medical reference tokens, 442 drug references, and 94 dose/unit events. Batch latency uses 600 measurements; Omi says ElevenLabs endpoints were timed from Frankfurt in September 2026.
- Context
- Omi Health sells a competing commercial medical speech-to-text product. Treat this benchmark conservatively as a community/vendor report, not a neutral independent replication. Omi does not state an immutable model revision, complete decoder parameters, or confidence intervals. Results apply only to the stated Omi test edition and route.
Page 1 of 2
Popularity compared
How often the model is searched for, used and mentioned, compared with every model of its category.
Popularity index
0 to 100, higher is more popular
20 of 83 models
As of November 2026 · Source: gradually.ai popularity index
Over time
Weekly values from October 18, 2026 to November 6, 2026
Scribe v2 MedicalAmazon Nova 2 Sonic 0Eleven Multilingual STS v2 0Eleven Music v2.5 0Eleven Text to Sound v2 0
Method changes in the timeline, a jump at these points is no market event:
- 1November 1, 2026: Value only with search or usage data, 30-day attention
What is gaining popularity right now, across models, vendors, harnesses and AI subscriptions, is collected in All AI trends.
Similar models
More models of the same kind as Scribe v2 Medical, chosen by model line, developer, size, price and release date.
- Eleven v3ElevenLabs · same developer
- Scribe v2ElevenLabs · same developer
- Eleven v3 ConversationalElevenLabs · same developer
- Scribe v2 RealtimeElevenLabs · same developer
- Eleven Flash v2.5ElevenLabs · same developer
- Eleven Multilingual STS v2ElevenLabs · same developer
- Eleven Text to Sound v2ElevenLabs · same developer
- Eleven Music v2.5ElevenLabs · same developer
All specifications
Architecture
Input and output
Watermarking and provenance
AI watermarking refers to invisible signals embedded in the output. Visible marks and provenance metadata are listed separately. Unknown means there is insufficient evidence for that particular field.
- AI watermarking
- Unknown
- no source
- Watermarking technique
- Not known
- no source
Licence and access
API
Further details
- Medical speech
- Over 90 languages; ElevenLabs reports 35% fewer transcription errors on clinical audio than Scribe v2
- Source: Medical speech
- Intended use
- For clinical transcription, not for diagnosis or treatment recommendations
- Source: Intended use
Sources and data date
Show all 15 sources
Benchmark sources at a glance
Which independent evaluators tested this model. This is coverage, not a quality ranking.
No active result from the reviewed external evaluators can currently be attributed to this model. Other source evidence remains available below.
Without vendor claims and historical or disputed results; those stay labelled in the single values.
| Type | Evidence and data date |
|---|---|
| Research status | Research date October 15, 2026. 9 source URLs checked. This documents the inspected sources, not an exhaustive inventory of every publication. |
| Not found in the inspected sources | independent-benchmark Note No independent-evaluator result for exact Scribe v2 Medical was found; the clinical rows in this bundle are published by ElevenLabs and remain vendor-reported. |
| Not found in the inspected sources | independent-benchmark Note No independent-evaluator result for exact Scribe v2 Medical was found; its clinical ASR rows remain vendor-reported. |
| Not published | Eka Medical ASR subset N Note The article reports 3,619 samples for the full dataset but no scored counts for the clinical-sentence or isolated-term subsets. |
| Additional source | ElevenLabs model documentation (retrieved September 24, 2026; October 15, 2026) · ElevenLabs Models documentation · Editorial description reviewed October 2, 2026 |
| Additional source | ElevenLabs model evaluation (retrieved October 15, 2026; October 17, 2026; October 18, 2026) |
| Additional source | Omi Health Medical Speech-to-Text Benchmark (retrieved October 17, 2026; October 18, 2026) |
| Additional source | Deepgram Nova-3 Medical Multilingual article (retrieved October 18, 2026) |
| Additional source | Model metadata (retrieved October 15, 2026)1234 |
| Additional source | Model metadata (retrieved October 17, 2026) |
| Additional source | OpenRouter: Popularity index (derived), CC BY 4.0 |
| Additional source | Vercel AI Gateway: Popularity index (derived), CC BY 4.0 |
| Additional source | Ollama: cumulative downloads for the popularity index |
| Additional source | Replicate: cumulative runs for the popularity index |
| Additional source | Google Trending Now: limited feed selection for Germany and the US |
| Additional source | Creative Commons Attribution 4.0 |